Guard Column cartridge, Bidentate C8 2.o, replacement, 2.0 mm ID x 10 mm long cartridge packed with 2.2 um, 120 A phase. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 40208‑PG3 Cogent Bidentate C8 2.0 Guard Column Cartridge is a single replacement cartridge designed for UHPLC and high‑pressure analytical systems, providing essential protection against particulates, contaminants, and strongly retained compounds.

Each cartridge is:

  • 2.0 mm ID × 10 mm length

  • Packed with 2.2 µm, 120 Å TYPE‑C™ silica hydride Bidentate C8 2.0 phase

  • Constructed in stainless steel housing with SS frits

The cartridge is individually packaged in a protective Delrin™ case, preventing drying, contamination, or physical damage prior to installation.

⚠️ Requires guard column holder (sold separately)

Designed for 2.1 mm UHPLC Columns

This cartridge is optimized for:

  • 2.1 mm ID analytical and UHPLC columns

  • Sub‑2 µm particle methods

  • LC‑MS and high‑sensitivity workflows

Proper guard matching ensures:

  • Minimal band broadening despite small particle size

  • Maintained high efficiency and resolution

  • Consistent retention and reproducibility

Why Use a Single Guard Cartridge

A single‑cartridge configuration is ideal when:

  • Testing different guard phases during method development

  • Using multiple analytical column chemistries

  • Replacing cartridges individually as needed

  • Maintaining flexibility without committing to multi‑packs

This provides maximum flexibility for precision workflows and optimization.

Why Use UHPLC Guard Column Protection

UHPLC columns using 2.2 µm particles are highly sensitive to:

  • Particulate contamination

  • Strongly retained or irreversible compounds

  • Matrix buildup from injected samples

  • Pressure increases due to blockage

The 40208‑PG3 cartridge acts as a critical sacrificial layer, helping to:

  • Preserve UHPLC column efficiency and resolution

  • Prevent rapid pressure buildup

  • Extend column lifetime

  • Maintain consistent analytical performance

Cartridges can be replaced quickly without disturbing the analytical column setup.

Bidentate C8 2.0™ Guard Phase Advantages

Using the same phase as your analytical column ensures:

  • Matched retention and selectivity behavior

  • Seamless analyte transfer

  • No need for method adjustment

Compared to C18 phases, Bidentate C8:

  • Reduces excessive hydrophobic retention

  • Improves recovery of amine‑containing compounds

  • Provides alternative selectivity for complex matrices

  • Supports fast equilibration in gradient methods

Cogent TYPE‑C™ Technology Benefits

Silica Hydride Surface

  • Reduced silanol activity

  • Improved peak shape for basic analytes

  • Lower secondary interactions

High‑Pressure Stability

  • Designed for UHPLC / sub‑2 µm workflows

  • Performs reliably under elevated pressures

  • Maintains performance over extended use

Faster Equilibration

  • Reduced cycle times

  • Improved throughput for high‑efficiency methods

Typical Applications

  • UHPLC and LC‑MS analytical methods

  • Pharmaceutical and bioanalytical workflows

  • High‑resolution separations

  • Complex sample matrices

  • Methods using sub‑2 µm Bidentate C8 columns

 